DGI.Simpl.Ross.RossTalkDriver 1.0.0

SIMPL Ross Talk Driver

SIMPL and SIMPL+ modules that wraps the DGI Framework Ross Talk Driver and the DGI SIMPL Communication Adapter so it can be used in SIMPL Windows applications

Ross Talk driver communicates with Ultrix Routers or any other video router that uses RossTalk protocol It will connect to the video router, send the appropriate command and then it will disconnect if no other commands are sent withing 60 seconds

Inputs:

External Connectivity

Use these inputs to connect to the communication method of your choice. You can use the Out of the Box SIMPL TCP/IP Client, or DGI's SIMPL TCP Client

  • ExternalConnect_F: Connect to the TCP/IP client symbol Connect-F output.
  • ExternalStatus: Connect to the TCP/IP client symbol Status output.
  • ExternalRx$: Connect to the TCP/IP client symbol Rx$ output.

Debug

  • LogLevel: Set the level of logging to be displayed in the Console (If running in an appliance) or the ErrorLog (If running in a virtual server). 0 = None, 1 = Error, 2 = Warning, 3 = Info, 4 = Debug, 5 = Trace

Ross Talk

  • Out[1..128]: Change the analog value of any of these signals to the source your want the output to display. The driver will automatically connect to the video switcher, send the command and disconnect. If no other commands are sent within 60 seconds, the driver will disconnect from the video switcher.

Outputs:

External Connectivity

  • ExternalConnect: Connect to the TCP/IP client symbol Connect input.
  • ExternalTx$: Connect to the TCP/IP client symbol Tx$ input.

Parameters:

  • Level: Sets the levels the router will interact with. Defaults to 1. Single levels and ranges can be mixed in the list. Example: "1,3,4-8,12-17"
  • MaximumSources: Sets the maximum number of sources the router will interact with. Defaults to 16.
  • MaximumDestinations: Sets the maximum number of sources the router will interact with. Defaults to 16.
  • BlankingSource: Source used to blank the video. This source will be selected, when the source to route is 0. Normally the last programed source. Defaults to 17. This is done to maintain compatibility with other video switchers and routers, when 0 is used to blank the video.
  • WaitBetweenMessages: Ticks (Hundredth's of a second) to wait between continuous messages. Modify this value if the messages are arriving too fast for the router to parse. It default to 60t (600ms).
  • PanelId: User or Panel ID. Defaults to 0

No packages depend on DGI.Simpl.Ross.RossTalkDriver.

Initial Release

This package has no dependencies.

Version Downloads Last updated
1.0.0 2 1/2/2024